Product Highlights
AC/DC Voltage Measurement
:
Accuracy
:
Range
600.0 mV
Resolution
0.1 mV
50 Hz to 60 Hz ± (% of Rdg + counts)
± (1 % + 3)
60 Hz to 5000 Hz ± (% of Rdg + counts
± (% of Rdg + counts) 600.0 mV 0.1 mV ± (1 % + 3)
Low-Pass Filter Voltage (1587 FC only)
:
Range:
600.0 mV
Resolution
0.1 mV
50 Hz to 60 Hz ± (% of Rdg + Counts)
± (1 % + 3)
60 Hz to 400 Hz ± (% of Rdg + Counts
+ (2 % + 3) - (6 % - 3)
DC voltage measurement
:
Range:
6.000 V dc
Resolution
0.001 V
Accuracy 1587 FC 1 ± (% of Rdg + Counts)
± (0.09 % + 2)
Accuracy 1577 1 ± (% of Rdg + Counts
± (0.2 % + 2)
DC millivolts measurement
:
Range
600.0 mV dc
Resolution
0.1 mV
Accuracy 1587 FC ± (% of Rdg + Counts)
± (0.1 % + 1)
Accuracy 1577 ± (% of Rdg + Counts
± (0.2 % + 1)
DC and AC current measurement
:
Range
AC 45 Hz to 1000 Hz : 400 mA
Resolution
0.1 mA
Accuracy 1587 FC ± (% of Rdg+Counts)
± (1.5 % + 2)1
Accuracy 1577 ± (% of Rdg+Counts)
± (2 % + 2)1
Burden voltage (Typical)
2 mV/mA
Ohms measurement
:
Range
600.0 Ω
Resolution
0.1 Ω
Accuracy 1587 FC1 + (% of Rdg+Counts) Accuracy 15771 +
± (0.9 % + 2)
Accuracy 15771 + (% of Rdg+Counts)
± (1.2 % + 2)
Diode test (1587 FC only)
:
Diode test indication
Display voltage drop: 0.6 V at 1.0 mA nominal test current:
Accuracy
± (2 % + 3)
Continuity test
:
Continuity indication
Continuous audible tone for test resistance below 25 Ω and off above 100 Ω. Maximum reading; 1000 Ω
Open circuit voltage
<8.0 V
Short circuit current
1.0 mA typical
Overload protection
1000 V rms
Response time
>1 m sec
Frequency measurement
:
Range
99.99 Hz
Resolution
0.01 Hz
Accuracy ± (% of Rdg+Counts)
± (0.1 % + 1)
Product Description
Technical Parameter
Tell Us What You Need