Product independently developed by Aowei Technology
Operates under extremely low pressure conditions, suitable for domestic water purifiers, hospitals, laboratory water purification systems, and for treating tap water, well water, and other low-salinity water sources.
Environment · Technology · Life
Test Conditions:
-
Test Solution Concentration (NaCl): 500 ppm
-
Test Solution pH: 7.5
-
Test Solution Temperature: 25°C
-
Single Membrane Element Recovery: 50%-60%
-
Test Pressure: 100 psi (0.69 Mpa)
Ultimate Test Conditions:
-
Inlet Water Free Chlorine Concentration: <0.1 ppm
-
Maximum Inlet Water SDI15: 5
-
Continuous Operation Water pH Range: 3~10
-
Chemical Cleaning Water pH Range: 2~12
-
Maximum Inlet Water Temperature: 45°C
-
Maximum Operating Pressure: 300 psi (2.07 Mpa)
-
Maximum Pressure Drop for a Single Membrane Element: 10 psi (0.07 Mpa)