Home/Laboratory Equipment/Experimental Consumables/Dual-energy Model --- ISD‑NFB4016/

Hangzhou Rayin Technology Co,Ltd.
ZheJiang-HangZhou, ChinaX‑ray Dual‑Energy Intelligent Foreign Object & Defect Detection System – ISD‑NFB4016 Series
Product Introduction
The X‑ray Dual‑Energy Intelligent Foreign Object & Defect Detection System utilizes X‑ray detection principles, a new Raytina image‑enhancement engine, advanced AI technology, and dual‑energy detection algorithms to perform dual‑analysis of product density and material composition. It achieves high‑precision, highly adaptable detection of foreign objects (residual bones, metal, glass, stones, plastic, rubber, and other micro‑foreign matter) and defects (counting, missing parts, etc.), providing effective technical assurance for improving production quality and efficiency for enterprises.

STRUCTURE
:
Order Model
ISD‑NFB4016 Series
Tunnel Opening Width
400mm
Tunnel Opening Height
160 mm
Overall Dimensions
2042 (H) × 1301 (L) × 987 (W) mm
Overall Weight
380 kg
Housing Material
Stainless steel (SUS 304)
CONVEYING SYSTERM
:
Conveyor Belt Material
Food‑grade PU
Conveyor Belt Width
440 mm
Conveyor Belt Height from Ground
800±50mm
Conveyor Belt Speed
10–60 m/min
Max. Load
10 kg
X-RAY SYSTERM
:
X-ray Tube Voltage
40–80 kV
X-ray Tube Current
4000-8000μA
X-ray Power
350 W
Detector
0.1 mm Multi‑Exposure Sensor
DETECTION SENSITIVITY
:
Stainless Steel Ball (Φ)
0.2 mm
Stainless Steel Wire
0.2*2mm
Glass Ball (Φ)
0.8 mm
Ceramic Ball (Φ)
0.8 mm
Algorithm Support
Foreign Object/Defect Detection
COMPLETE MACHINE CONFIGURATION:
Ingress Protection RatingDrive Section: IP66; Other Areas: IP66
Tested Product FormPackaged, Bulk
Rejection MethodNG Stop; Automatic Rejection (Optional rejection mechanism)
Alarm ModeSound & light alarm
Display Mode21.5‑inch Touch Screen, 1920 × 1080 Resolution
Cooling MethodIndustrial A/C & Dedicated Air Circulation System
Radiation Protection4‑layer Endless Protective Curtains at Entrance & Exit
Radiation Safety≤1μSv/h
Power SupplyAC 220 V, 50/60 Hz
Operating Temperature-10~40℃
Operating Humidity30–97% RH, Non‑condensing
InterfacesEthernet, USB; Supports MES Integration
Product Description
Technical Parameter
Configuration List
Related Pictures
Leave Message