The basic working principle of an electric heating steam generator is as follows: Through an automatic control device, the liquid controller or high, medium, and low electrode probes provide feedback control over the opening and closing of the water pump, the duration of water supply, and the heating time of the furnace. The high steam pressure, set by a pressure relay, causes the furnace water level to drop continuously as steam is continuously output. When the water level is low (mechanical) or medium (electronic), the water pump automatically replenishes water. When the water level reaches high, the water pump stops replenishing water. At the same time, the electric heating tubes inside the furnace continue to heat the furnace, continuously generating steam. The pointer-type pressure gauge on the panel or top immediately displays the steam pressure value. The entire process can be automatically displayed by indicator lights.
Features of Electric heating steam generator RYD-48KW
- The high thermal efficiency benefits from the furnace bodydesign and excellent adjustment and testing. The steamgenerator has high thermal efficiency and fast heating time.
- It operates fully automatically with intelligent control and a high degree of automation, requiring no human supervision and saving time and effort.
- The equipment is rationally designed and operates stably. Each piece of equipment undergoes rigorous testing before leaving the factory, ensuring safety and peace of mind.
- It adopts direct current heating, and the water flows through the heat exchanger to become hot water, which is directly supplied to the furnace body. The water storage capacity is small, and the water is recycled to avoid waste.
- Pure copper core water pump, durable and quieter.
Parameters of Electric Heating Steam Generator Series
| Parameter | RYD-24kw | RYD-48kw | RYD-72kw | RYD-96kw | RYD-192kw |
|---|---|---|---|---|---|
| Evaporation Capacity | 35 kg/h | 70 kg/h | 100 kg/h | 140 kg/h | 280 kg/h |
| Rated Working Pressure | 0.7 MPa | 0.7 MPa | 0.7 MPa | 0.7 MPa | 0.7 MPa |
| Boiler Thermal Efficiency | 95% | 95% | 95% | 95% | 95% |
| Effective Water Volume | 29 L | 29 L | 29 L | 29 L | 29 L*2 |
| Power Consumption | 24 kw | 48 kw | 72 kw | 96 kw | 192 kw |
| Water Inlet Diameter | DN15 | DN15 | DN15 | DN15 | DN15 |
| Drain Outlet Diameter | DN25 | DN25 | DN25 | DN25 | DN25 |
| Steam Outlet Diameter | DN20 | DN20 | DN20 | DN20 | DN25 |
| Safety Valve Diameter | DN20 | DN20 | DN20 | DN20 | DN30 |
| Control System Type | Dedicated for Electric Heating | Dedicated for Electric Heating | Dedicated for Electric Heating | Dedicated for Electric Heating | Dedicated for Electric Heating |
| Power Supply Voltage | 380V / 50Hz | 380V / 50Hz | 380V / 50Hz | 380V / 60Hz | 380V / 50Hz |
| Overall Dimensions (L×W×H) | 780×600×1230 mm | 810×600×1280 mm | 810×600×1380 mm | 810×600×1380 mm | 810×960×1380 mm |
| Weight | 70 kg | 80 kg | 90 kg | 100 kg | 190 kg |