Home/Accessories/Consumables/Electrical/Fluke 1508 Insulation Resistance Tester (Digital Megohmmeter)/

Guangzhou Boyuan Beverage Machinery Co., Ltd.
GuangDong-GuangZhou, ChinaMain product features:
Main Features
AC/DC Voltage Measurement
:
AC/DC Voltage:
600V
Accuracy
Resolution: 0.1 V 50 Hz to 400 Hz ± (% reading + number) ± (2% + 3)
Input Impedance:
3 MΩ (nominal), < 100 pF
Common Mode Rejection Ratio (1 kΩ unbalanced):
> 60 dB at DC, 50 or 60 Hz
Overload Protection:
600 V effective or DC
Resistance Measurement
:
Range:
20.00 Ω: 0.01 Ω 200.0 Ω: 0.1 Ω 2000 Ω: 1 Ω 20.00 kΩ: 0.01 kΩ
Accuracy:
± (1.5% + 3)
Overload Protection:
2 V effective or DC
Open Circuit Test Voltage:
> 4.0 V, < 8 V
Short Circuit Current:
> 200.0 mA
Insulation Resistance Measurement
:
Measurement Range:
0.01 MΩ to 10 GΩ
Test Voltage:
50 V, 100 V, 250 V, 500 V, 1000 V
Test Current Accuracy:
± 20%, 0%
Short Circuit Test Current:
1 mA, nominal value
Auto Discharge:
When C = 1 μF or more, discharge time < 0.5 s
Live Circuit Detection Function:
Before starting the test, if the voltage detected is greater than 30 V, the test is prohibited.
Maximum Capacitive Load:
Can work under a load of up to 1 μF.
General Technical Specifications
:
Maximum Voltage Applied to Any Terminal:
600 V AC effective or DC
Storage Temperature:
-40 °C to 60 °C (-40 °F to 140 °F)
Operating Temperature:
-20 °C to 55 °C (-4 °F to 131 °F)
Temperature Coefficient:
0.05 × (specified accuracy) / °C, when temperature < 18 °C or > 28 °C (< 64 °F or > 82 °F)
Relative Humidity:
0% to 95% at 10 °C to 30 °C (50 °F to 86 °F) 0% to 75% at 30 °C to 40 °C (86 °F to 104 °F) 0% to 40% at 40 °C to 55 °C (104 °F to 131 °F)
Vibration Resistance:
Random, 2 g, 5-500 Hz, meets MIL-PRF-28800F, Class 2 requirements
Impact Resistance:
1 meter drop, meets IEC 61010-1 Category 2, 6 sides, rubber mat requirements
EMC Compliance:
In a 3 V/m RF field, accuracy = specified accuracy (EN 61326-1:1997)
Safety:
Complies with ANSI/IEEE 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No. 1010.1 and IEC/EN 61010-1 2nd Edition for CAT IV 600 V equipment requirements
Certification:
CSA, meets standards CSA/CAN C22.2 No. 1010.1; TUV, meets standards IEC/EN 61010-1 2nd Edition
Battery:
4 AA type batteries (NEDA 15A or IEC LR6)
Battery Life:
For insulation resistance measurement: At room temperature, new batteries can perform at least 1000 insulation tests. Test conditions: 1000 V, to 1 MΩ, duty cycle 5 seconds on, 25 seconds off.
Battery Life:
For resistance measurement: At room temperature, new batteries can perform at least 2500 resistance measurements. Test conditions: 1 Ω, duty cycle 5 seconds on, 25 seconds off.
Dimensions:
5.0 cm high × 10.0 cm wide × 20.3 cm long (1.97 in high × 3.94 in wide × 8.00 in long)
Weight:
550 g (1.2 lb)
IP Rating:
IP40
Altitude:
Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V Non-operating (storage): 12,000 m
Overload Capacity:
110% range
Product Description
Technical Parameter
Tell Us What You Need